95 research outputs found

    Rational and intuitive approaches to music composition: The impact of individual differences in thinking/learning styles on compositional processes

    Get PDF
    This study explores the idea that there are two different types of composers, those that use a rational process of composition involving pre-planning and use of external systems and those that use an intuitive process that involves trial and error or other exploratory means for composing. It focuses on further understanding these patterns of thought as they are found in the compositional processes of student composers as well as investigating their learning preferences. The study examines the compositional processes of five composition students from the Sydney Conservatorium of Music selected using their results on the SOLAT (Style Of Learning And Thinking) measure (Torrance, McCarthy & Kolesinski, 1988). After interviewing the five participants, a model was developed that explained how rational and intuitive patterns of thought were used at different levels. The macroprocesses of participants were found to sit on a continuum between rational and intuitive whilst at the micro-level participants were seen to use a mixture of both processes. The interview participants were also asked to comment on their preferred activities for learning composition. It was found that the participants believed their compositional processes were something that they developed themselves and they wanted a more personal approach to learning. The findings have implications for both teachers of composition and their students

    The role of input in second language oral ability development in foreign language classrooms: a longitudinal study

    Get PDF
    The current project longitudinally investigated the extent to which first-year Japanese university students developed their second language (L2) oral ability in relation to increased input in foreign language classrooms. Their spontaneous speech was elicited at the beginning, middle and end of one academic year, and then judged by linguistically trained coders for pronunciation, fluency, vocabulary and grammar qualities. According to the statistical analyses, the total amount of input (operationalized as number of English classes taken and L2 use outside of classrooms) was significantly related to the participants’ quick and immediate development of fluency and lexicogrammar during the first semester. Their pronunciation development was mixed, either subject to continuous change over two academic semesters (for prosody) or limited within the timeframe of the study (for segmentals). Similar to naturalistic L2 speech learning, the findings support the multifaceted role of input in different areas of oral proficiency development in foreign language classrooms

    What is the Prevalence of Hip Intra-Articular Pathologies and Osteoarthritis in Active Athletes with Hip and Groin Pain Compared with Those Without? A Systematic Review and Meta-Analysis

    Get PDF
    Background In athletes, hip and groin pain is considered to be associated with hip intra-articular pathologies and hip osteoarthritis (OA). A greater understanding of the relationship between hip and groin pain and imaging fndings is required. Objective Our objective was to undertake a systematic review and meta-analysis to determine the prevalence of hip intraarticular pathologies and hip OA in athletes with and without hip and groin pain. Methods Seven electronic databases were searched on 29 January 2018 for studies investigating the prevalence of hip intraarticular pathologies and hip OA using X-ray, magnetic resonance imaging, magnetic resonance arthrography or computed tomography. The search, study selection, quality

    Increased end-expiratory pressures improve lung function in near-term newborn rabbits with elevated airway liquid volume at birth

    Get PDF
    Approximately 53% of near-term newborns admitted to intensive care experience respiratory distress. These newborns are commonly delivered by cesarean section and have elevated airway liquid volumes at birth, which can cause respiratory morbidity. We investigated the effect of providing respiratory support with a positive end-expiratory pressure (PEEP) of 8 cmH(2)O on lung function in newborn rabbit kittens with elevated airway liquid volumes at birth. Near-term rabbits (30 days; term = 32 days) with airway liquid volumes that corresponded to vaginal delivery (similar to 7 mL/kg, control, n = 11) or cesarean section (similar to 37 mL/kg; elevated liquid (EL), n = 11] were mechanically ventilated (tidal volume= 8 mL/kg). The PEEP was changed after lung aeration from 0 to 8 to 0 cmH(2)O (control, n = 6; EL, n = 6), and in a separate group of kittens, PEEP was changed after lung aeration from 8 to 0 to 8 cmH(2)O (control, n = 5; EL, n = 5). Lung function (ventilator parameters, compliance, lung gas volumes, and distribution of gas within the lung) was evaluated using plethysmography and synchrotron-based phase-contrast X-ray imaging. EL kittens initially receiving 0 cmH(2)O PEEP had reduced functional residual capacities and lung compliance, requiring higher inflation pressures to aerate the lung compared with control kittens. Commencing ventilation with 8 cmH(2)O PEEP mitigated the adverse effects of EL, increasing lung compliance, functional residual capacity, and the uniformity and distribution of lung aeration, but did not normalize aeration of the distal airways. Respiratory support with PEEP supports lung function in near-term newborn rabbits with elevated airway liquid volumes at birth who are at a greater risk of suffering respiratory distress.NEW & NOTEWORTHY Term babies born by cesarean section have elevated airway liquid volumes, which predisposes them to respiratory distress. Treatments targeting molecular mechanisms to clear lung liquid are ineffective for term newborn respiratory distress. We showed that respiratory support with an end-expiratory pressure supports lung function in near-term rabbits with elevated airway liquid volumes at birth. This study provides further physiological understanding of lung function in newborns with elevated airway liquid volumes at risk of respiratory distress.Developmen

    Higher CPAP levels improve functional residual capacity at birth in preterm rabbits

    Get PDF
    BACKGROUND: Preterm infants are commonly supported with 4-8 cm H2O continuous positive airway pressures (CPAP), although higher CPAP levels may improve functional residual capacity (FRC).METHODS: Preterm rabbits delivered at 29/32 days (similar to 26-28 weeks human) gestation received 0, 5, 8, 12, 15 cm H2O of CPAP or variable CPAP of 15 to 5 or 15 to 8 cm H2O (decreasing similar to 2 cm H2O/min) for up to 10 min after birth.RESULTS: FRC was lower in the 0 (6.8 (1.0-11.2) mL/kg) and 5 (10.1 (1.1-16.8) mL/kg) compared to the 15 (18.8 (10.9-22.4) mL/kg) cm H2O groups (p = 0.003). Fewer kittens achieved FRC > 15 mL/kg in the 0 (20%), compared to 8 (36%), 12 (60%) and 15 (73%) cm H2O groups (p = 0.008). While breathing rates were not different (p = 0.096), apnoea tended to occur more often with CPAP < 8 cm H2O (p = 0.185). CPAP belly and lung bulging rates were similar whereas pneumothoraces were rare. Lowering CPAP from 15 to 5, but not 15 to 8 cm H2O, decreased FRC and breathing rates.CONCLUSION: In all, 15 cm H2O of CPAP improved lung aeration and reduced apnoea, but did not increase the risk of lung over-expansion, pneumothorax or CPAP belly immediately after birth. FRC and breathing rates were maintained when CPAP was decreased to 8 cm H2O.Developmen

    Increased upconversion performance for thin film solar cells a trimolecular composition

    Get PDF
    Photochemical upconversion based on triplet triplet annihilation TTA UC is employed to enhance the short circuit currents generated by two varieties of thin amp; 64257;lm solar cells, a hydrogenated amorphous silicon a Si H solar cell and a dye sensitized solar cell DSC . TTA UC is exploited to harvest transmitted sub bandgap photons, combine their energies and re radiate upconverted photons back towards the solar cells. In the present study we employ a dual emitter TTA UC system which allows for signi amp; 64257;cantly improved UC quantum yields as compared to the previously used single emitter TTA systems. In doing so we achieve record photo current enhancement values for both the a Si H device and the DSC, surpassing 10 3 mA cm 2 sun 2 for the amp; 64257;rst time for a TTA UC system and marking a record for upconversion enhanced solar cells in general. We discuss pertinent challenges of the TTA UC technology which need to be addressed in order to achieve its viable device application

    A knee brace alters patella position in patellofemoral osteoarthritis: A study using weight bearing magnetic resonance imaging.

    Get PDF
    OBJECTIVE: To assess using weight bearing MRIs, whether a patellar brace altered patellar position and alignment in patellofemoral joint (PFJ) osteoarthritis (OA). DESIGN: Subjects age 40-70 years old with symptomatic and a radiographic K-L evidence of PFJOA. Weight bearing knee MRIs with and without a patellar brace were obtained using an upright open 0.25 Tesla scanner (G-Scan, Easote Biomedica, Italy). Five aspects of patellar position were measured: mediolateral alignment by the bisect offset index, angulation by patellar tilt, patellar height by patellar height ratio (patellar length/patellar tendon length), lateral patellofemoral contact area and finally a measurement of patellofemoral bony separation of the lateral patellar facet and the adjacent surface on the femoral trochlea (Figure 1). RESULTS: Thirty participants were recruited (mean age 57 SD 27.8; BMI 27.8 SD 4.2); 17 were females. Four patients had non-usable data. Main analysis used paired t tests comparing within subject patellar position with and without brace. For bisect offset index, patellar tilt and patellar height ratio there were no significant differences between the brace and no brace conditions. However, the brace increased lateral facet contact area (p =.04) and decreased lateral patellofemoral separation (p = .03). CONCLUSION: A patellar brace alters patellar position and increases contact area between the patella and femoral trochlea. These changes would lower contact stress at the PFJ. Such changes in patella position in weight bearing provide a possible biomechanical explanation for the success of the PFJ brace in clinical trials on PFJOA

    Increasing Respiratory Effort With 100% Oxygen During Resuscitation of Preterm Rabbits at Birth

    Get PDF
    Background: Spontaneous breathing is essential for successful non-invasive respiratory support delivered by a facemask at birth. As hypoxia is a potent inhibitor of spontaneous breathing, initiating respiratory support with a high fraction of inspired O2 may reduce the risk of hypoxia and increase respiratory effort at birth. Methods: Preterm rabbit kittens (29 days gestation, term ~32 days) were delivered and randomized to receive continuous positive airway pressure with either 21% (n = 12) or 100% O2 (n = 8) via a facemask. If apnea occurred, intermittent positive pressure ventilation (iPPV) was applied with either 21% or 100% O2 in kittens who started in 21% O2, and remained at 100% O2 for kittens who started the experiment in 100% O2. Respiratory rate (breaths per minute, bpm) and variability in inter-breath interval (%) were measured from esophageal pressure recordings and functional residual capacity (FRC) was measured from synchrotron phase-contrast X-ray images. Results: Initially, kittens receiving 21% O2 had a significantly lower respiratory rate and higher variability in inter-breath interval, indicating a less stable breathing pattern than kittens starting in 100% O2 [median (IQR) respiratory rate: 16 (4–28) vs. 38 (29–46) bpm, p = 0.001; variability in inter-breath interval: 33.3% (17.2–50.1%) vs. 27.5% (18.6–36.3%), p = 0.009]. Apnea that required iPPV, was more frequently observed in kittens in whom resuscitation was started with 21% compared to 100% O2 (11/12 vs. 1/8, p = 0.001). After recovering from apnea, respiratory rate was significantly lower and variability in inter-breath interval was significantly higher in kittens who received iPPV with 21% compared to 100% O2. FRC was not different between study groups at both timepoints. Conclusion: Initiating resuscitation with 100% O2 resulted in increased respiratory activity and stability, thereby reducing the risk of apnea and need for iPPV after birth. Further studies in human preterm infants are mandatory to confirm the benefit of this approach in terms of oxygenation. In addition, the ability to avoid hyperoxia after initiation of resuscitation with 100% oxygen, using a titration protocol based on oxygen saturation, needs to be clarified
    • …
    corecore